Venteville, agent of Marinelec
Venteville

Marinelec Technologies

Marinelec Technologies

Experts in Electronic Monitoring and Alarm Systems

Marinelec Technologies specializes in the design and manufacturing of monitoring and alarm systems for all types of vessels. Their product range includes:
  • Fire detection systems
  • Tank level measurement and detection
  • Navigation light panels
  • General alarm systems
  • Bilge detection alarms
  • Monitoring and alarm systems
  • Emergency telegraphs
  • Bridge watch alarm systems
  • Energy management solutions
  • Custom products upon request

Tailored Solutions for All Vessels

Marinelec Technologies creates custom systems to meet client needs and comply with major classification societies like Bureau Veritas and Det Norske Veritas. They supply systems for various ships, including passenger vessels, commercial vessels, LNG carriers, warships, and yachts.

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

contact us.
Addressable Detectors
Marinelec Technologies / Fire Detection Systems / Inland Shipping

Addressable Detectors and Bases

 
product options

Device Compatibility

The addressable detectors, manual call points, and loop-powered sounders are fully compatible with the Marinelec Phoenix V2 fire detection system.
 
These devices include:

 

Detectors and Bases

Partnumber Description
TOADR Optical smoke detector.
TTADR Heat detector. Available in 50°C, 65°C, 80°C
TMCADR Multisensor detector.
TFUVADRW Flame detector delivered with base and mounting bracket.
EMADR Base for addressable detector.
KITSEAP Watertight kit for TOADR, TTADR, TMCADR.
TTEXADR Intrinsically safe heat detector.
EMEXADR Base for intrinsically safe detector.
TOEXADR Intrinsically safe optical smoke detector.
 

Manual Call Points

Partnumber Description
DMADRIS Manual call point with isolator IP24D.
DMADREIW1 Waterproof manual call point with isolator IP67.
DMEXADRE Intrinsically safe manual call point IP67.
 

Sirens and Beacons

Partnumber Description
SDIR24_1CDE Multi-tone red siren, 24VDC, 100dB, IP65, MED.
FSDIR24_10CDE Multi-tone red sounder/beacon 24 VDC , 1J, 100dB, IP65, MED

 

Phoenix V2: Addressable Fire Detection and Alarm Control Panel

The Phoenix V2 offers a versatile solution for fire detection, supporting up to 126 devices per loop with the Apollo protocol. It integrates seamlessly with a range of devices, providing flexibility for various system configurations.
 
The system allows users to allocate any number of devices to any zone, making customization easy for specific needs. For a smooth installation, planning is crucial. Each device needs a unique address and a label with up to 40 characters to indicate its location. Devices should also be grouped into zones based on fire detection design standards. Users can configure the control panel effortlessly with Phoenix Soft V2 for optimal performance.

 

Learn more on the Phoenix V2 product page.
 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

Discover the PHOENIX V2 Fire Detection System.

Visit the product page.
 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

AVAS
Marinelec Technologies / Alarm, Control & Monitoring system / Inland Shipping

AVAS (Audio visual alarm sequencer)

 
part no.

AVAS

product options

AVAS System: Comprehensive Audible and Visual Alarm Management

The AVAS system is a powerful and flexible audible and visual alarm sequencer designed to manage key safety signals onboard vessels. Its main functions include:

  • General alarm activation
  • Control of the ship’s whistle and foghorn
  • Signal management to and from the Public Address System

Equipped with a 7-inch color touchscreen, AVAS provides a clear, intuitive display of control functions, making it easy to operate. Designed to meet the highest standards, it is approved by Bureau Veritas for reliable management of ship alarms. Furthermore, the system can be expanded with additional functions, such as light column control (AVASXM), enhancing its versatility.
 

Display and Equipment Features

The AVAS system features a 7-inch color touchscreen (AVAS_HMI) that offers precise control. In larger wheelhouses, up to two supplementary screens can be added to improve visibility and accessibility. The modular design includes a processor module (AVAS_CPU) and the touchscreen interface, ensuring that the system is scalable and easy to maintain.
 

Key Functions and Inputs

AVAS performs several critical functions, including:

  • General alarm signal control (7 short blasts, 1 long blast)
  • Manual call activation
  • Management of signals to and from the Public Address System
  • Whistle sequencer with a customizable signal option

In addition, AVAS supports multiple input signals for comprehensive management, such as:

  • Abandon ship signal
  • General alarm
  • Fire alarm
  • Manual internal call
  • Whistle control
  • Public address system signals
  • Two additional inputs for future expansion

Outputs and Integration

The AVAS system provides the following outputs to ensure full control and safety integration:

  • Whistle control (24Vdc – 0.5 A)
  • System fault indication
  • Sound signal output
  • Warning light output
  • Public address system inhibition

By integrating advanced control, multiple inputs, and flexible expansion options, the AVAS system ensures a reliable, adaptable, and robust solution for managing critical onboard alarms and signals.

 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

Conventional Detectors
Marinelec Technologies / Fire Detection Systems / Inland Shipping

Conventional Detectors and Bases

 
product options

Device Compatibility

The Conventional detectors, manual call points, and loop-powered sounders are fully compatible with the Marinelec Philae fire detection system.
 
These devices include:

Detectors and Bases

Partnumber Description
TOA Optical smoke detector.
TTA Heat detector. Available in 50°C, 65°C, 80°C
TMCA Multisensor detector.
TFUVAW Flame detector delivered with base and mounting bracket.
EMBCAO Base for addressable detector.
KITSEAP Watertight kit for TOADR, TTADR, TMCADR.
TTD Heat detector.
EMBCD Base for TTD and TOD detector.
TOD Optical smoke detector.
KITSED Watertight kit for TTD and TOD.
TOEXA Intrinsically safe optical smoke detector.
TTEXA Intrinsically safe heat detector.
EMEXA Base for intrinsically safe detector.
TMEXA Intrinsically safe multisensor detector.
EMBCEXA Base for intrinsically safe detector.

Manual Call Points

Partnumber Description
DMA Manual call point with isolator IP24D.
DME Waterproof manual call point IP67.
DMEXAE Intrinsically safe manual call point IP67.
DMD Indoor manual call point IP33.
DMED Waterproof manual call point IP66

Sirens and Beacons

Partnumber Description
SDIR24_1CDE Multi-tone red siren, 24VDC, 100dB, IP65, MED.
FSDIR24_10CDE Multi-tone red sounder/beacon 24 VDC , 1J, 100dB, IP65, MED

 

PHILAE Conventional Fire Detection System

The PHILAE is a versatile conventional fire detection system that supports 4 to 28 zones. It has a total capacity for up to 512 detectors or manual call points, providing extensive coverage for fire safety.
 
The system’s modular design allows the connection of up to three PHILAE_EM extension modules, each offering 8 additional zones, expanding the capacity to a maximum of 28 zones. Each zone can accommodate up to 32 devices, such as manual call points, optical smoke, heat, and flame detectors, including intrinsically safe options.
 
Additionally, the PHILAE system supports up to three repeaters, such as PHILAE_RP, which can log events for locations like the Engine Control Room or Fire Control Room, ensuring comprehensive monitoring.
 
Learn more on the Philae product page.
 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

 

Discover the PHILAE Fire Detection System.

Visit the product page.
 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

ECOMER - Analytical econometer
Marinelec Technologies / Alarm, Control & Monitoring system / Inland Shipping

ECOMER Analytical Econometer System

 
part no.

ECOMER

product options

Analytical Econometer System Overview

ECOMER is designed to help reduce fuel consumption and emissions on ships. It is available in two systems, with optional add-ons:

  • ECOMER EMB (Embedded)
  • ECOMER TC (Curve Plotter)

 

ECOMER EMB: Intelligent Fuel Efficiency System

EMB is an advanced system that assists in optimizing ship operations by collecting, analyzing, and displaying real-time fuel consumption data. The system provides the captain with actionable insights to:

  • Generate fuel savings
  • Reduce polluting emissions

EMB Inputs

The system collects data based on vessel type and configuration, including:

  • Tank levels (sensors)
  • Diesel consumption of engines (flow meters and digital links)
  • Propulsive efficiency (engine speed, torque, propeller pitch)
  • Energy production (sensors/digital links)
  • Power consumption per station (sensors)
  • Equipment status (on/off)
  • Ship position and status (GPS, inertial unit, etc.)
  • Environmental data (temperature, brightness, wind)
  • Time stamping

EMB Outputs

  • Real-time data displayed on a dashboard and graphs
  • Visualization of pollutant emission levels
  • Actionable recommendations for efficiency
  • Data archiving for later analysis

 

ECOMER TC: Shore-Based Analysis Tool

TC is a software tool designed to analyze ship data collected by ECOMER EMB or similar systems. It helps shipowners improve operations and guide future investment decisions.

TC Inputs

Data collected onboard is transmitted via GSM, satellite, or USB. Inputs include:

  • Tank levels
  • Diesel fuel consumption
  • Propulsive efficiency (engine speed, torque, propeller pitch)
  • Energy production
  • Power consumption per station
  • Vessel status (position, speed, trim)
  • Environmental data (temperature, wind)
  • Operational data (tonnage, towing, passengers)

TC Outputs

  • Customizable dashboard and graphs for data comparison
  • Visualization of fuel consumption and emission levels
  • Comparative analysis across ships in the same fleet

By utilizing ECOMER, shipowners and operators can make data-driven decisions to improve fuel efficiency and reduce emissions.

 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

LYNX V3+ BNWAS
 
part no.

LYNX V3+

product options

LYNX V3+ Bridge Navigational Watch Alarm System

The LYNX V3+ BNWAS continuously monitors the awareness of the officer on watch, whether in the engine room or on the bridge. In the event that the officer becomes unable to carry out their duties, the system promptly alerts other officers and crew members. Furthermore, the system includes a timer that the officer must reset periodically, up to every 12 minutes, by pressing a luminous button. Additionally, the activation of the safety equipment is secured through a password or, alternatively, with an optional external key switch, providing added control and security.
 
Moreover, the device integrates seamlessly with repeater panels, enabling remote resets and providing escalating alarms (stage one, two, and three) as required, ensuring timely alerts across the vessel.
 

Key Features

  • Automatic Power Switchover: Seamlessly transitions between main and emergency power supplies while issuing an alarm notification.
  • Dimmable Display: Easily adjustable for day or night mode, ensuring visibility under all conditions.
  • Alarm Levels & Timer: Displays both the alarm level and the remaining countdown time clearly.
  • Emergency Call Button: Provides instant alert capabilities in case of emergencies.
  • Multilingual Interface: Offers support for English, French, and Spanish, enhancing usability for diverse crews.
  • Officer Selection: Allows for the selection and naming of the officer on duty (available with LYNX B BUS remote panels).
  • External Alarm Transfer: Integrates with the “LYNX network” to transfer alarms across different parts of the vessel.
  • Countdown Reset Options: The system can be reset using motion sensors or linked navigational equipment via a serial link (NMEA 0183), adding flexibility to the reset process.

 

Outputs

  • Stage 1 Visual and Acoustic Alarms: Immediate outputs to the wheelhouse for awareness.
  • Stage 2 Alarm: Directs signals to officer cabins.
  • Stage 3 Alarm: Issues alerts to crew areas, ensuring widespread notification.
  • System Fault Output: A dry contact (N.C., 0.5A max) signals any system issues.
  • RS485 Serial Output: For reporting data to NMEA 0183 (VDR) equipment.
  • Switched Power Output: Provides 24VDC to power associated products and panels.
  • Bus Remote Panel Output: Supports connections to LYNX REB BUS, LYNX B BUS, LYNX EC BUS, and the motion sensor interface LYNX MSI.

 

Inputs

  • External Countdown Reset: Two dry contact inputs enable manual reset from remote locations.
  • Automatic Mode Activation: Connects to LYNX KM or other navigational equipment (Note: automatic mode should not be used on SOLAS vessels).
  • Access Protection: An input for securing system access via key (LYNX KI) or alarm transfer.

Overall, the LYNX V3+ ensures reliable and safe watchkeeping operations through its password-protected system, providing enhanced security and functionality.

 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

MACCS Alarm and monitoring system
Marinelec Technologies / Alarm, Control & Monitoring system / Inland Shipping

MACCS Alarm and Monitoring System

 
part no.

MACCS

product options

MACCS Alarm and Monitoring System

The MACCS is a versatile safety system designed to monitor both digital and analog inputs while controlling various onboard equipment. It supports up to 64 inputs/outputs, making it highly adaptable. Its 7″ color touchscreen interface offers clear, precise displays of alarms and controls, ensuring ease of operation.

 
The MACCS system is designed and approved to provide several essential features:

  • Bilge alarm monitoring
  • Technical alarm monitoring
  • Tank level measurement
  • Analog sensor measurement
  • Control of equipment such as lighting, pumps, valves, and fans

Furthermore, it is fully configurable via a user-friendly setup menu on the touchscreen.

 

Display and Equipment

The MACCS system is equipped with a flush-mounted 7″ color touchscreen (MACCS_HMI) and can support two additional screens if required. This modular system consists of a central CPU module (MACCS_CPU) with 8 digital inputs, which can be expanded with up to 7 modules (or 2 modules for the 12VDC version) to reach a maximum of 64 inputs/outputs.

 

Inputs and Outputs

The system offers the following capabilities:

 
Analog Inputs:

  • 8 inputs (0/10VDC or 4/20mA)
  • Time delay adjustable from 0 to 180 seconds
  • 4 alarm thresholds per channel
  • 21-point calibration

 
Digital Inputs:

  • 8 inputs, monitored or not, with configurable N.O./N.C.
  • Time delay from 0 to 180 seconds
  • Individual channel inhibition

 
Digital Outputs:

  • 8 outputs, 1A@24VDC, with N.O. and N.C. contacts
  • Time delay from 0 to 180 seconds
  • Maintained or impulse operation
  • Emergency manual activation via micro switches

 

CPU and Power Management

The centralized processor manages the inputs/outputs and provides seamless switching between main and emergency power supplies. It includes:

  • 24VDC output for powering MACCS_HMI
  • Two RS485 ports for external communication (NMEA or MODBUS RTU)
  • 8 monitored digital inputs, 1 configurable input, and 5 integrated outputs (1 x 24VDC, 4 x digital).

This ensures reliable, efficient monitoring and control for critical ship systems.

 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

NORMA.CP
 
part no.

NORMA.CP

product options

Navigation Lights Monitoring and Control System

The NORMA navigation lights alarm system provides reliable monitoring and control of up to 14 navigation lights, powered at 24VDC or 230VAC, with power ranging from 0.5W to 65W. It offers precise control through the NORMA.CP operator interface, working in conjunction with NORMA.CPU and NORMA.PWR modules. The interface can be personalized with navigation light names or a ship’s mimic using a customizable printout.
 
The NORMA.CPU monitors and controls up to 8 navigation lights, while NORMA.PWR ensures efficient power management with alarms and automatic/manual switchover between two sources.
 

Key Features

  • Power Supply Management: Seamlessly switches between manual and automatic modes with alarms for safe power management.
  • Dual-pool Protection: Controls navigation lights without using a common wire for added safety.
  • Compatibility: Works with filament and LED lights at 24VDC or 230VAC (max 40W at 24VDC, 65W at 230VAC).
  • LED Lifetime Alarm: Provides alerts for the lifespan of LED navigation lights.
  • Failure Detection: Identifies filament breakage, short circuits, power supply, and fuse failures.
  • Day/Night Mode: Adjusts lighting settings based on ambient conditions.
  • Serial Connections: Supports integration with control panels, AMS, and VDR systems for enhanced monitoring.
  • Capacity for Expansion: Monitors up to 14 lights with two NORMA.CPU cards.
  • Emergency Control: Offers direct emergency control switches on the board for quick access.

Inputs and Outputs

Inputs:

  • Control power supply (24VDC)
  • Acknowledgement, dimming, and test inputs (N.O. push buttons)
  • Local/remote switch, ON/OFF switch, and main/emergency switch inputs
  • 8 navigation light control inputs

Outputs:

  • 8 navigation light outputs and status indication outputs
  • 3 relay outputs for buzzer, light fault, and power fault (N.O. 24VDC/1A)
  • 1 system fault relay output (N.C. 24VDC/1A)
  • 4 signaling outputs for power supplies and LED lifetime alarms

Serial Outputs:

  • NORMA.CP Control Panel (RS485, Modbus RTU)
  • VDR output (RS485, IEC61162-1)
  • AMS output (RS485, Modbus RTU)

With its comprehensive monitoring and control capabilities, the NORMA system ensures safe, reliable operation of navigation lights for any vessel.

 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

Carina -> Philae
 
part no.

CARINA

product options

The Carina is obsolete, and its successor is the Philae.
 

More Information

If you have any questions or require more information about the Philae system.

See Philae product page.

 

 

 

CL09 replaced by Sirius
Marinelec Technologies / Alarm, Control & Monitoring system

Obsolete – CL09

 
part no.

CL09

product options

The light column CL09 is obselete and replaced by the light column Sirius.
 

More Information

If you have any questions or require more information about the Sirius system.

See Sirius product page.

DI09 replaced by Philae
 
part no.

DI09

product options

The DI09 is obsolete, and its successor is the Philae.
 

More Information

If you have any questions or require more information about the Philae system.

See Philae product page.

 

Orion V3 - Emergency telegraph
Marinelec Technologies / Alarm, Control & Monitoring system

ORION V3 Engine Telegraph

 
part no.

ORION V3

product options

ORION V3: Engine Telegraph System

The ORION V3 is a critical safety device designed to ensure smooth communication between the engine room and the wheelhouse. It guarantees efficient transmission of orders and is ideal for maritime operations requiring precise command relays. The system connects 2 to 5 stations via a single cable using Power Line Communication, simplifying installation.
 
The ORION V3 is available in two versions: flush or cabinet-mounted, and supports three languages—English, French, and Spanish.
 

Key Functions

  • Channels: The system supports up to 11 channels, including a “STOP” channel.
  • Station Support: Comes standard with 2 stations, with the option to extend to 3 or 5.
  • Channel Selection: Managed through an ON/OFF switch with clear LED status indicators.
  • Audible Signals: The internal buzzer provides a minimum of 75dB for audible alerts.
  • Dimmable Light Indicators: Adjustable for day/night modes.
  • Luminous Indicator Testing: Includes a built-in test function.
  • Critical Orders: Ensures priority signals are handled efficiently.
  • System Fault Detection: Notifies users in case of a control bus failure.
  • Control Takeover: Available for systems with 3 or more stations, allowing flexibility in emergencies.

Outputs

  • Siren Output: 24VDC/100mA for external sirens.
  • System Fault Output: NC dry contact (1A max, 24VDC) for fault notifications.
  • Critical Order Output: NO dry contact (1A max, 24VDC) for emergency orders.

Serial Communication

  • RS485 Output: Handles two functions:
    • Bridge Panel: Sends data to the VDR (Voyage Data Recorder) at 4800 baud, following the IEC 61162-2 standard.
    • Engine Panel: Communicates with the ORION printer using ASCII protocol.

The ORION V3 provides reliable, seamless communication between key ship stations, ensuring safety, compliance, and operational efficiency.
 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

Philae
Marinelec Technologies / Fire Detection Systems / Inland Shipping

PHILAE

 
part no.

PHILAE

product options

PHILAE Conventional Fire Detection System

The PHILAE is a versatile conventional fire detection system that supports 4 to 28 zones. It has a total capacity for up to 512 detectors or manual call points, providing extensive coverage for fire safety.
 
The system’s modular design allows the connection of up to three PHILAE_EM extension modules, each offering 8 additional zones, expanding the capacity to a maximum of 28 zones. Each zone can accommodate up to 32 devices, such as manual call points, optical smoke, heat, and flame detectors, including intrinsically safe options.
 
Additionally, the PHILAE system supports up to three repeaters, such as PHILAE_RP, which can log events for locations like the Engine Control Room or Fire Control Room, ensuring comprehensive monitoring.
 

Display

The Philae Fire Detection and Alarm System provides clear status indication with yellow and red LEDs for zone monitoring. Additionally, the system includes bilingual text (English and French by default, with other languages available upon request). An integrated buzzer ensures immediate audio alerts, while customizable labels allow easy zone identification, offering enhanced clarity and personalization.
 

Input

The system features one dedicated general alarm input. This input activates a sequence of 7 short blasts followed by 1 long blast on the siren output, ensuring proper alarm signaling in critical situations.
 

Key Functions

  • Microswitch Configuration: Simplifies system setup and customization.
  • Access Code Protection: Ensures only authorized personnel can modify protected functions.
  • Zone Monitoring: Detects short circuits, open circuits, or missing detectors, ensuring real-time system reliability.
  • Automatic Power Switchover: Seamlessly shifts from main to emergency power supply, with an accompanying alarm.
  • Repeater with Log Events: Records critical data, aiding in future analysis and system audits.

Outputs

The Philae system is equipped with several outputs:

  • Siren Output: Monitored, 24VDC with a 0.5A maximum capacity.
  • Fire Output: Dry contact, N.O., with a 1A maximum capacity.
  • Fault Output: Dry contact, N.C., with a 1A maximum capacity.
  • Unacknowledged Fire Alert (2 min): Dry contact, N.O., with a 1A maximum capacity.

Communication

  • NET1 Output: Connects to VDR via IEC-61162-2 and NMEA 0183 standards (ASCII, 4800 bauds, 8/N/1).
  • NET2 Output: Supports Modbus RTU RS485 SLAVE for communication with external equipment (9600 bauds, 8/N/1). A dedicated port is available if a repeater is used.

The Philae Fire Detection and Fire Alarm System is certified with the Marine Equipment Directive (MED), ensuring compliance with industry standards and offering reliable fire safety management.
 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.
 

Discover the compatible Conventional Detectors and Bases.

Visit the product page.
 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

PHILAE Extension Module
Marinelec Technologies / Fire Detection Systems / Inland Shipping

PHILAE Extension Module

 
product options

PHILAE Conventional Fire Detection System

The PHILAE is a versatile conventional fire detection system that supports 4 to 28 zones and support the PHILAE Extension Module. It has a total capacity for up to 512 detectors or manual call points, providing extensive coverage for fire safety.
 
The system’s modular design allows the connection of up to three PHILAE_EM extension modules, each offering 8 additional zones, expanding the capacity to a maximum of 28 zones. Each zone can accommodate up to 32 devices, such as manual call points, optical smoke, heat, and flame detectors, including intrinsically safe options. PHILAE Extension Module
 
Additionally, the PHILAE system supports up to three repeaters, such as PHILAE_RP, which can log events for locations like the Engine Control Room or Fire Control Room, ensuring comprehensive monitoring.
 

Display

The Philae Fire Detection and Alarm System provides clear status indication with yellow and red LEDs for zone monitoring. Additionally, the system includes bilingual text (English and French by default, with other languages available upon request). An integrated buzzer ensures immediate audio alerts, while customizable labels allow easy zone identification, offering enhanced clarity and personalization.
 

Input

The system features one dedicated general alarm input. This input activates a sequence of 7 short blasts followed by 1 long blast on the siren output, ensuring proper alarm signaling in critical situations.
 

Key Functions

  • Microswitch Configuration: Simplifies system setup and customization.
  • Access Code Protection: Ensures only authorized personnel can modify protected functions.
  • Zone Monitoring: Detects short circuits, open circuits, or missing detectors, ensuring real-time system reliability.
  • Automatic Power Switchover: Seamlessly shifts from main to emergency power supply, with an accompanying alarm.
  • Repeater with Log Events: Records critical data, aiding in future analysis and system audits.

 

Outputs

The Philae system is equipped with several outputs:

  • Siren Output: Monitored, 24VDC with a 0.5A maximum capacity.
  • Fire Output: Dry contact, N.O., with a 1A maximum capacity.
  • Fault Output: Dry contact, N.C., with a 1A maximum capacity.
  • Unacknowledged Fire Alert (2 min): Dry contact, N.O., with a 1A maximum capacity.

 

Communication

  • NET1 Output: Connects to VDR via IEC-61162-2 and NMEA 0183 standards (ASCII, 4800 bauds, 8/N/1).
  • NET2 Output: Supports Modbus RTU RS485 SLAVE for communication with external equipment (9600 bauds, 8/N/1). A dedicated port is available if a repeater is used.

The Philae Fire Detection and Fire Alarm System is certified with the Marine Equipment Directive (MED), ensuring compliance with industry standards and offering reliable fire safety management.
 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

Discover the compatible Conventional Detectors and Bases.

Visit the product page.
 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

PHOENIX Monitor
Marinelec Technologies / Fire Detection Systems / Inland Shipping

PHOENIX Monitor

 
part no.

PHOENIX MONITOR

product options

Phoenix Monitor: Fire Detection Software Solution

The Phoenix Monitor, developed by MARINELEC, integrates seamlessly with the Phoenix V2 fire detection panel to provide an ergonomic, user-friendly interface for ship fire detection systems. Its customizable features make monitoring and responding to fire-related events more efficient.
 

Key Features

The Phoenix Monitor offers several advantages:

  • Customizable Interface: Users can tailor the interface to fit their specific needs, ensuring it aligns with the vessel’s layout.
  • Clear Event Visualization: Any event is displayed visually and clearly, which speeds up decision-making and enables quicker interventions.
  • Event History Logging: The software keeps a detailed log of all events, allowing for comprehensive analysis.

 

Hardware Configuration

To run Phoenix Monitor, you need a PC with the following minimum specifications:

  • Memory: 512MB of RAM
  • Operating System: Windows 7 or 10 (64-bit)
  • Communication: RS485 port or USB with an RS485 converter (using the Modbus RTU protocol)
  • Display: Full HD resolution (1920×1080)
  • Operator Stations: Up to 2 stations (master and slave)

 

Software Configuration

The software offers robust customization options, including:

  • Vessel View Import: Users can import and assign vessel views (e.g., general profile, deck sections).
  • Automatic System Import: The system configuration can be automatically imported via the Phoenix V2 panel.
  • Drag & Drop Zone Assignment: Each zone and point can be assigned on the views using an intuitive drag-and-drop feature.

 

User Interface

The interface provides comprehensive fire monitoring, including:

  • Global Monitoring: Displays status at the profile level and by bridge.
  • Zone Diagnostics: Offers status and diagnostics for each zone and point.
  • System Diagnostics: Monitors the Phoenix V2 network, communication, loops, and electrical networks.
  • Event History: Logs all events for later analysis.

With Phoenix Monitor, the ship’s fire detection system becomes more responsive and easier to manage, enhancing safety and efficiency.

 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

Discover the PHOENIX V2 Fire Detection System.

Visit the product page.
 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

Marinelec Technologies / Fire Detection Systems / Inland Shipping

PHOENIX V2

 
part no.

PHOENIX V2

product options

Phoenix V2: Addressable Fire Detection and Alarm Control Panel

The Phoenix V2 is an advanced fire detection and alarm control panel with two detection loops, supporting up to 126 devices per loop using the Apollo protocol. It works seamlessly with various devices, including automatic detectors, manual call points, loop-powered sounders, and I/O modules. This flexible system allows users to assign devices to any zone, making it adaptable for different requirements.
 
To ensure smooth installation, careful planning is crucial. Each device needs a unique address and a label of up to 40 characters to identify its location. Group devices into zones according to fire detection standards. Manage the panel configuration easily using Phoenix Soft V2.
 

Device Compatibility and System Design

The Phoenix V2 supports a wide range of devices, such as optical smoke detectors, heat detectors, multi-sensor detectors, switch monitors, sounders, relay modules, and bell controllers. It also integrates with conventional detection systems. Each loop provides an addressing range from 1 to 126, offering flexible options for various building layouts.
 

Important Considerations for Fire Detection Cables

To prevent interference or malfunction, fire alarm circuits must be kept separate from other circuits. Key considerations include:

  • Minimizing electromagnetic interference from nearby circuits.
  • Preventing insulation breakdown of either fire alarm or other circuits.
  • Reducing fire risks caused by faults in other circuits.

Proper care is also needed when installing or removing other circuits in shared ducts or trunking to avoid damaging fire alarm circuits.
 
Following these guidelines ensures that the Phoenix V2 system is installed and maintained effectively, providing reliable fire detection and alarm performance.
 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

Discover the compatible Addressable Detectors and Bases.

Visit the product page.
 

Contact Us for More Information

If you have any questions or require spare parts for your Marinelec system.

Contact us.

Venteville Homepage